Infrared Thermometers From TPI (Test Products International)

Thoroughly testing and diagnosing high efficiency HVACR systems or large surface areas can be labor intensive and expensive. Using the appropriate non-contact thermometer can reduce man hours and help insure system performance more easily, accurately and affordably.

Model

Description

Additional Info

368:
Infrared Thermometers (IR)
368


Close-focus, pocket-size infrared thermometer without laser
  • Pocket-size
  • Distance to spot ratio 1:1.17
  • Temperature range -7 to +248° F (-21 to 120°C).
  • Selectable Fahrenheit or Centigrade
  • Auto data hold
  • Min/max
  • Auto mode; continually scan surface temperatures in real-time

Product Sheet
Instruction Manual

370:
Infrared Thermometers (IR)


Measure 14 to 500°F (-10 to 260°C) with a non-gun style non-contact (IR) thermometer without laser
  • No laser
  • 0.1° resolution
  • Data hold
  • Distance to spot ratio 8:1

Product Sheet
Instruction Manual

371:
Infrared Thermometers (IR)

Measure 14 to 500°F (-10 to 260°C) with a non-gun style non-contact (IR) thermometer with laser sighting
  • Laser sighting
  • 0.1° resolution
  • Data hold
  • Distance to spot ratio 8:1

Product Sheet
Instruction Manual

375:
Infrared Thermometers (IR)

Combination non-contact (IR) and contact thermometer. 0 to 950°F (-18 to 510°C) IR and -40 to 2,192°F (-40 to 1200°C) contact; depending upon K-type probe
  • Non-contact (IR) range: 0 to 950°F (-18 to 510°C)
  • Contact range: -40 to 2,192°F (-40 to 1200°C) depending upon optional probe selected
  • Laser sighting
  • Distance to spot ratio 11.5:1
  • Adjustable emissivity (0.3 to 0.99)
  • °C and °F selectable
  • Record function (min/max)
  • Backlight

Product Sheet
Instruction Manual

376:
Infrared Thermometers (IR)

Combination non-contact (IR) and contact thermometer. -58 to 950°F (-50 to 510°C) IR and -40°F to 2,192°F (-40 to 1200°C) contact; depending upon K-type probe
  • Non-contact (IR) range: -58 to 950°F (-50 to 510°C)
  • Contact range: -40 to 2,192°F (-40 to 1200°C) depending upon optional probe selected
  • Laser sighting
  • Distance to spot ratio 11.5:1
  • Adjustable emissivity (0.3 to 0.99)
  • °C and °F selectable
  • Record function (min/max)
  • Backlight

Product Sheet
Instruction Manual

377:
Infrared Thermometers (IR)

Combination non-contact (IR) and contact thermometer. 0 to 1832°F (-18 to 1000°C) IR and -40 to 2,192°F (-40 to 1200°C) contact; depending upon K-type probe
  • Non-contact (IR) range: 0 to 1,832°F (-18 to 1000°C)
  • Contact range: -40 to 2,192°F (-40 to 1200°C) depending upon optional probe selected
  • Laser sighting
  • Distance to spot ratio 11.5:1
  • Adjustable emissivity (0.3 to 0.99)
  • °C and °F selectable
  • Record function (min/max)
  • Backlight

Product Sheet
Instruction Manual

380:
Infrared Thermometers

Measure -4 to +572°F (20 to 300°C), non-contact (IR) thermometer without laser
  • Repeatable measurements, 0.1° resolution readings
  • Temperature compensated for accurate readings
  • Hold function
  • Easy-to-use one button operation
  • °C and °F selectable
  • Distance to spot ratio 9:1
  • Easy to read LCD with backlight
  • Auto off

Product Sheet
Instruction Manual

381:
Infrared Thermometers

Measure -4 to +572°F (-20 to 300°C), non-contact (IR) thermometer with laser sighting
  • Repeatable measurements, 0.1° resolution readings
  • Temperature compensated for accurate readings
  • Hold function
  • Easy-to-use one button operation
  • °C and °F selectable
  • Distance to spot ratio 9:1
  • Laser sighting
  • Easy to read LCD with backlight
  • Auto off

Product Sheet
Instruction Manual



381F:
Infrared Thermometers

+/- 2°F accuracy between 32 and 158°F (Food Range), non-contact (IR) thermometer with laser sighting
  • Repeatable measurements, 0.1° resolution readings
  • Temperature compensated for accurate readings
  • Hold function
  • Easy-to-use one button operation
  • °C and °F selectable
  • Distance to spot ratio 4:1
  • Laser sighting
  • Easy to read LCD with backlight
  • Auto off

Product Sheet
Instruction Manual

383:
Infrared Thermometers

Measure -31 to +999°F (-35 to 537°C), non-contact (IR) thermometer with laser sighting
  • Repeatable measurements, 0.1° resolution readings
  • Temperature compensated for accurate readings
  • Hold function
  • Easy-to-use one button operation
  • °C and °F selectable
  • Distance to spot ratio 9:1
  • Laser sighting
  • Easy to read LCD with backlight
  • Auto off

Product Sheet
Instruction Manual

384:
Infrared Thermometers

Measure up to 1,832°F, non-contact (IR) thermometer with laser sighting
  • Temperature range: 0°F to 1832°F (-18°C to 1000°C)
  • Repeatable measurements, 0.1° resolution readings
  • Temperature compensated for accurate readings
  • Hold function
  • Easy-to-use one button operation
  • °C and °F selectable
  • Distance to spot ratio 9:1
  • Laser sighting
  • Easy to read LCD with backlight
  • Auto off

Product Sheet
Instruction Manual